Digital scintillation gamma spectrometer *
APPLICATION
The device is intended for gamma - ray detection at radiological monitoring of environmental objects in nuclear energetics, products of industry and agriculture, medicine, etc.
COMPLETE SET
-
Digital scintillation gamma detecting unit with NaI(Tl) detector (Ø63mm x 63mm)
-
Gamma analysis software SpectraLineGP
-
CD with drivers and software utilities
-
User’s manual
TECHNICAL CHARACTERISTICS
|
Parameter |
Value |
|
Measured energy range, MeV |
0.05 - 3 |
|
Relative energy resolution on 662 keV (137Cs) line, %, no more than |
8 |
|
Integral nonlinearity, %, no more than |
±1 |
|
Operation mode setup time, min, no more than |
30 |
|
Time gain instability in 24 hours of continues operation, %, no more than |
±1 |
|
Temperature gain instability, %/°C, no more than |
±0.1 |
|
Maximum input count rate, c-1, no less than |
1.5*105 |
|
Relative change of resolution on 662 keV (137Cs) at the maximum input count rate, %, no more than |
15 |
|
Relative shift of 662 keV (137Cs) at the maximum input count rate, %, no more than |
1 |
|
Number of spectrum channels |
1024 |
|
LLD adjustment range, spectrum channels |
1 - 1000 |
|
LLD adjustment step, spectrum channels |
1 |
|
Communication serial interface type |
USB 1.1 |
|
Interface cable length, m |
4 |
|
Supply voltage (from the USB bus), V |
+5 |
|
Power consumption, VA, no more than |
1 |
|
Protection class |
IP54 |
|
Operation temperature range, °C |
+5 - +40 |
|
Weight (without laptop), kg, no more than |
2.1 |
|
Overall dimensions (without laptop), mm |
Ø88x345 |
Software functionalities:
-
automatic peaks search with the required sensitivity level;
-
the energy, FWHM and peak pattern calibrations;
-
peaks parameters determination - position, FWHM, area;
-
calculation results can be saved to a text file;
-
efficiency “curves” can be obtain with the efficiency calibration;
-
activity calculation by various methods;
-
use the true-coincident factors to correct the gamma-emission intensity;
-
the measured spectra and processing results saving to database for the analysis of the specified criterions convergence of the repeated measurements;
-
simultaneous processing of any spectra number;
-
the peak pattern calibration with several spectrum peaks in different energy ranges;
-
numeric and visual control of the calibrations results;
-
any measurement tracts number;
-
independent control of all channels - start, stop, etc.
For additional information, please contact us: sales@bsi.lv.
* Digital scintillation gamma detecting unit is available on stock and ready to be shipped to the customer as soon as required.
|
|
|
|
| |