Main -> Products -> CdZnTe/CdTe Detectors & associated electronics -> Large Volume Spectroscopy Detectors
Large Volume Spectroscopy Detectors
APPLICATION
  • Nuclear materials verification;
  • Environmental monitoring;
  • Control of illicit trafficking of nuclear materials;
  • Portable spectrometers;
  • Monitoring of nuclear material flow.

FEATURES

  • High efficiency;
  • High energy resolution;
  • Room temperature operation;
  • Small dimensions and weight;
  • Wide detection range.

TECHNICAL CHARACTERISTICS

 
Detector
Detector volume, cm3
Bias voltage, V
Energy resolution (FWHM) at 662 keV, keV
Peak-to-Compton Ration at 662 keV
Standard grade
Super grade
Standard grade
Super grade
CZT/500(S)
0.5
< 1500
< 30
< 18
> 2.3
> 4.0

Parameter

Value

Basic

 

Detectors type

CdZnTe quasi-hemispherical detector

Detector high voltage polarity

Positive

Range of recommended operation temperature

0 to 40 °C

Dimensions

 

CZT/500(S)
Length (without connector)

Diameter

33mm

23mm

Connector

 

CZT/500(S)

BNC

For additional information, please contact us: detectors@bsi.lv.
Ganibu dambis 26, P.O.Box 33, LV-1005, Riga, Latvia
Tel.(+371)67383947, Fax (+371)67382620