Borehole Gamma Spectrometer
APPLICATION

Borehole Gamma Spectrometer is used for:
  • Determination of underground orientation of transuranium ores in their natural beddings (headings, mines, boreholes);
  • High precision gamma-spectrometry of radionuclides at inspection of sea bed, water sealed mines, water filled boreholes, radionuclide migration in groundwater;
  • Gamma-spectrometry at neutron-activation method of substance analysis.
COMPLETE SET

Borehole Gamma Spectrometer consists of:

  1. Spectrometric Probe
  2. Ground workstation
Spectrometric probe consists of:
  • Spectrometric gamma-radiation detection unit based on high-purity germanium detector with built-in preamplifier of signals.
  • Alternatives for Cooling System:
    • Cryoaccumulator,
    • Stirling cryocooler;
    • Liquid nitrogen,
  • Spectrometric device;
  • Protective housing;
  • Well-logging borehole connection cable;

Ground workstation consists of

  • Data processing and analysis software SpectraLineGP;
  • Personal computer;
  • Borehole cable and connectors set.
TECHNICAL CHARACTERISTICS
 

Parameter

Value

Cryoaccumulator

Stirling cryocooler

Liquid nitrogen

Relative efficiency (with respect to 3’’ x 3’’ NaI detector and Co-60 source mounted 25 cm above the detector) at 1.33 MeV g-photon*

10 %

Resolution at 122 KeV at 103 s-1

Resolution at 1.33 MeV

< 1000 eV
< 1.9 KeV

< 1.5 KeV
< 3.2 KeV

< 1000 eV
< 2.00 KeV

Energy range of detector operation

100 KeV – 3.5 MeV

Diameter of protective housing

65 mm

80 mm

70 mm

Length of Borehole Probe

1450 mm

1250 mm 1550 mm
Cooling time

< 10 hours

< 12 hours

< 8 hours

Autonomous operation time

> 8 hours

> 15000 hours

> 10 hours

* - Borehole detection unit could be equipped with HPGe detector with efficiency up to 40%.
 
For additional information, please contact us: sales@bsi.lv
 
Ganibu dambis 26, P.O.Box 33, LV-1005, Riga, Latvia
Tel.(+371)67383947, Fax (+371)67382620