Digital scintillation gamma spectrometer *
APPLICATION
 
The device is intended for gamma - ray detection at radiological monitoring of environmental objects in nuclear energetics, products of industry and agriculture, medicine, etc.
 
COMPLETE SET
  • Digital scintillation gamma detecting unit with NaI(Tl) detector (Ø63mm x 63mm)
  • Gamma analysis software SpectraLineGP
  • CD with drivers and software utilities
  • User’s manual
TECHNICAL CHARACTERISTICS
 
Parameter
Value
Measured energy range, MeV
0.05 - 3
Relative energy resolution on 662 keV (137Cs) line, %, no more than
8
Integral nonlinearity, %, no more than
±1
Operation mode setup time, min, no more than
30
Time gain instability in 24 hours of continues operation, %, no more than
±1
Temperature gain instability, %/°C, no more than
±0.1
Maximum input count rate, c-1, no less than
1.5*105
Relative change of resolution on 662 keV (137Cs) at the maximum input count rate, %, no more than
15
Relative shift of 662 keV (137Cs) at the maximum input count rate, %, no more than
1
Number of spectrum channels
1024
LLD adjustment range, spectrum channels
1 - 1000
LLD adjustment step, spectrum channels
1
Communication serial interface type
USB 1.1
Interface cable length, m
4
Supply voltage (from the USB bus), V
+5
Power consumption, VA, no more than
1
Protection class
IP54
Operation temperature range, °C
+5 - +40
Weight (without laptop), kg, no more than
2.1
Overall dimensions (without laptop), mm
Ø88x345
 
Software functionalities:
  • automatic peaks search with the required sensitivity level;
  • the energy, FWHM and peak pattern calibrations;
  • peaks parameters determination - position, FWHM, area;
  • calculation results can be saved to a text file;
  • efficiency “curves” can be obtain with the efficiency calibration;
  • activity calculation by various methods;
  • use the true-coincident factors to correct the gamma-emission intensity;
  • the measured spectra and processing results saving to database for the analysis of the specified criterions convergence of the repeated measurements;
  • simultaneous processing of any spectra number;
  • the peak pattern calibration with several spectrum peaks in different energy ranges;
  • numeric and visual control of the calibrations results;
  • any measurement tracts number;
  • independent control of all channels - start, stop, etc.
For additional information, please contact us: sales@bsi.lv.

* Digital scintillation gamma detecting unit is available on stock and ready to be shipped to the customer as soon as required.